Gas · Communications
Data Logger
The data logger records gas volumes and consumption profiles for commercial and industrial meters. The integrated GSM/GPRS modem is battery-powered. VPN-GSM communication with a static IP inside the VPN ensures secure data transfer using current encryption methods, and the configuration software is free of charge. On request, the device can also push data automatically to a collection system or MDM (PUSH mode).
Key benefits
- Records gas volumes and consumption profiles for commercial and industrial meters
- Integrated battery-powered GSM/GPRS modem
- VPN-GSM communication with a static IP within the VPN for secure data transfer
- Configuration software supplied free of charge
- Automatic data transmission to a collection system or MDM (PUSH mode), on request
Applications
- Gas
- Accessory
- Smart
Technical data
Technical specifications
| Characteristic | Value |
|---|---|
| Housing | Plastic, with cable glands |
| Dimensions | W 120 × H 75 × D 58 mm (incl. cable glands) |
| Weight | 0.3 kg (incl. one device battery) |
| Degree of protection | IP 65 to EN 60529 |
| Ambient temperature | -25 °C…+60 °C |
| Maximum humidity | 93%, non-condensing |
| ATEX approval | Basic version. The manufacturer’s declaration confirms suitability for use in Zone 2 hazardous areas. Marking II3G Ex ic IIB T4 Gc |
| Inputs | 2 inputs (intrinsically safe), max. frequency 10 Hz. Pulse or status inputs. Alternatively, 2 inputs can be connected to an encoder index (Namur, SCR/SCR+) |
| Display | 8 digits. Displays all parameters, settings and archived values |
| Device power supply | One lithium battery, 3 V / 1.59 Ah |
| Modem power supply | One lithium battery, 3.6 V / 1.3 Ah. Alternatively, with a power supply unit (optional) |
| Data interfaces | Optical interface to IEC 62056-21 for parameterisation and archive reading. Serial RS232/RS485 or Ethernet interface as a plug-in module (optional) |
| Modem (integrated or plug-in module) | 2G (GPRS) or 3G (UMTS) modem. Antenna on the housing, in a protected position. Alternatively, external antenna (various cable lengths available) |
| Data communication | TCPServ, addressing via static IP in VPN (PULL) |
| Data protocols | IEC 62056-21. On special request: DLMS/COSEM, with AES-128 encryption and Galois/Counter mode |
Document centre
- Data Logger data sheet (RO)Download PDF
- Data Logger product passportDownload PDF
- DL SOFT software (RO)