Gas · Rotary gas meters
RABO® G16…G400 rotary gas meters
G16 / G25 / G40 / G65 / G100 / G160 / G250 / G400
The Honeywell Elster RABO G16-G400 rotary gas meter is based on decades of Elster-Instromet technology. It combines robust mechanical construction with modern digital integration and accurately measures natural gas and other filtered, non-corrosive gases in distribution networks, industrial facilities and commercial buildings. The meter is approved for custody transfer measurement and certified to MID, PED and ATEX / IECEx. Thanks to its positive displacement measuring principle, pipework configuration does not affect accuracy, allowing installation in compact systems without a straight inlet pipe section.
Key benefits
- Approved for fiscal metering of natural gas and filtered, non-corrosive gases
- Maintenance-free version, no oil filling required
- Ready for 100% hydrogen, fiscal and process metering
- Rotatable index for horizontal or vertical installation, any flow direction
- Ready for S1 ENCODER, secure digital transfer to volume converters and data loggers
- No straight inlet section required, ideal for compact installations
Applications
- Gas
- Rotary
- Industrial
- Commercial
- Hydrogen
Technical data
Technical specifications
Select a configuration to see its values
| Characteristic | Value |
|---|---|
| Nominal diameter | DN 32 mm |
| Type | G16 |
| Qmax | 25 m³/h |
| Qmin at 1:200 | Not applicable |
| Qmin at 1:160 | Not applicable |
| Qmin at 1:130 | Not applicable |
| Qmin at 1:100 | 0,25 m³/h |
| Qmin at 1:80 | 0,32 m³/h |
| Qmin at 1:65 | 0,4 m³/h |
| Qmin at 1:50 | 0,5 m³/h |
| Qmin at 1:30 | 0,8 m³/h |
| Qmin at 1:20 | 1,25 m³/h |
| Cyclic volume V | 0.87 (1.61*) dm³ |
| LF | 10 (1*) imp/m³ |
| HF | 11460 (6210*) imp/m³ |
| Δp air at Qmax | 0.9 mbar |
| Δp natural gas at Qmax | 0.6 mbar |
| Version | Oil-lubricated RABO |
| Gas temperature | -25 °C…+70 °C |
| Ambient temperature | -25 °C…+70 °C |
| Storage temperature | -40 °C…+70 °C |
| Operating pressure | Max. 20 bar |
| Degree of protection | IP67 (outdoor installation) |
| Housing | Aluminium or spheroidal graphite cast iron |
| MID approval | DE-12-MI002-PTB001 (PTB), pursuant to Directive 2014/32/EU |
| PED approval | CE-0085CN0022 (DVGW Cert GmbH), pursuant to Directive 2014/68/EU |
| ATEX approval | Zone 1, pursuant to Directive 2014/34/EU (ATEX) / IECEx |
| Medium | Natural gas, various filtered non-corrosive gases and 100% hydrogen (H₂) |
| Accuracy class | AC 1.0 |
| Reproducibility | < 0,1 % |
| Indexes | S1V (standard), S1 with display at 45°, S2. Optional: Absolute encoder S1D, double index S1D, double index MI-2D, MI-2 with display at 45° or 90°, S1-VR |
| Maximum permissible errors according to EN 12480 | ±1.0 % for Qt…Qmax; ±2.0 % for Qmin…Qt |
| Qt | Depends on the measuring range (e.g. 0.05 Qmax at >1:50) |
| Note * | Values in parentheses apply to the RABO CGG EBL150 version (overall length: 150 mm). |
| Note ** | Pressure loss values are typical values and depend on the test bench conditions. |
Document centre
- RABO data sheet (RO)Download PDF
- RABO data sheet (EN)Download PDF
- RABO data sheet (RU)Download PDF
- RABO presentation (EN)Download PDF
- RABO user manual (RO)Download PDF
- RABO user manual (EN)Download PDF
- RABO user manual (RU)Download PDF
- EU declaration of conformity RABO (EN / RO)
- EU-type examination certificate RABO
- EC-type examination certificate PED RABO (RO)
- EC-type examination certificate PED RABO (EN)