Gas · Ultrasonic gas meters
Q.Sonic®-max ultrasonic gas meter
DN 100…DN 600 (4"…24"), up to 36" on request
Multipath ultrasonic gas meters have become one of the leading methods for measuring high gas flow rates, particularly for custody transfer, thanks to their accuracy, wide dynamic range and low costs. As upstream piping can distort the flow profile, Q.Sonic-max is designed to meet and exceed the requirements of OIML R137, ISO 17089 accuracy class 0.5, AGA 9 and MID. The meter uses a patented 8-path configuration: two double-reflection swirl paths for linearity and stability, plus six direct paths for robustness and flow profile recognition. The reflected paths detect swirl, deposits or the presence of liquids, while the direct paths improve reliability in challenging gases, for example those with high CO2 content. The cybersecurity package (IEC 62443-4-1) includes TLS and encryption of sensitive data.
Key benefits
- 8-path configuration: 6 direct + 2 reflected swirl paths
- Typical uncertainty as low as 0.1 % after linearisation
- Extended diagnostics for swirl, deposits and liquids
- Reliable operation in CO2-rich gases
- Cybersecurity in accordance with IEC 62443-4-1, TLS encryption
- EnSuite software for configuration, diagnostics and condition monitoring
Applications
- Gas
- Ultrasonic
- Transmission
- Custody transfer metering
Technical data
Technical specifications
| Characteristic | Value |
|---|---|
| Path configuration | 8 paths (6 direct + 2 reflected swirl paths) |
| Typical uncertainty | 0.5 % (zero-flow calibration), 0.2 % (high-pressure calibration), 0.1 % (linearisation) |
| Repeatability | ≤ 0,05 % |
| Metrological approvals | MID, OIML R137 class 0.5, ISO 17089 class 0.5, AGA 9 |
| Dimensions | 4"…24" (DN 100…DN 600), up to 36" on request |
| Pressure classes | ASME 300…600 (others on request) |
| Body material | Low-temperature carbon steel (LTCS); stainless steel on request |
| Ambient temperature | Standard -40 °C…+60 °C; extended / MID -40 °C…+55 °C |
| Process temperature | Standard -40 °C…+60 °C; extended -40 °C…+80 °C; MID -40 °C…+55 °C |
| Degree of protection | IP66 (NEMA 4X) |
| Hazardous areas | ATEX, IECEx, FM |
| Power supply | 24 V c.c. (18…30 V), 10…20 W |
| Interfaces | 2 x serial (RS232/485), 1 x Ethernet, 2 x frequency, 2 x digital, 2 x analogue (4…20 mA), 1 x USB |
| Protocols | Modbus (ASCII, RTU, TCP/IP), UNIFORM, MMS, web server, TLS encryption |
| Display | 4.3" colour graphic, 7 capacitive keys, LEDs |
| Software | EnSuite (configuration, diagnostics, condition monitoring) |
| Application | Custody transfer and process metering of natural gas and other gases |
Document centre
- Q.Sonic®-max operating and maintenance manual (EN)Download PDF